INSTALLATION INSTRUCTIONS
1. Pass the female half coupling through the hole in the wall.
2. Position the upper claw (at the back of the indoor unit) on the upper hook of the
installation plate, gently rock the indoor unit from side to side to check that it is securely
hooked.
3. Temporarily place a cushioning material between the indoor unit and the wall as illustrated
below to make it easier to completely route the flexi hose through the wall. Remove the
cushioning material.
4. Gently push the lower part of the indoor unit up against the wall, then gently rock the indoor
unit from side to side, up and down to check that it is securely hooked.
Upper hook
Lower hook
Cushioning
material
Fig.8
4. Indoor unit installation
3. Drainage Installation
1. Run the drain hose sloping downward to ensure condensation water is being drained externally,
any rise in the drain hose will prevent condensation water to flow externally on gravity as
illustrated below (Fig. 7).
2. When connecting extension drain hose, insulate the connecting part of extension
drain hose with a shield pipe, avoiding any slack on the drain hose.
Do not form a rise
Do not put the hose
end into water
Fig.7
5. Piping and wrapping
Bundle the tubing, connecting cable with
tape securely and evenly as shown in Fig.9.
Because the condensed water from the
indoor unit is gathered in condensation
tray and should be piped out externally.
Indoor unit
Connective
pipe
Pipe room
Condensation tray
Wrapping belt
Connective
cable
Drain hose
Fig.9
Note: Route the flexi hose with female half coupling through the hole in the wall
from the rear of the indoor unit (right) or (left).
Condensation Water
Page view 7